dc.contributor.author | Tamayo Monsalve, Manuel A. | |
dc.contributor.author | Osorio, Gustavo | |
dc.contributor.author | Liliana Montes, Nubia | |
dc.contributor.author | López, Santiago | |
dc.contributor.author | Cubero, Sergio | |
dc.contributor.author | Blasco, José | |
dc.date.accessioned | 2021-02-10T12:38:44Z | |
dc.date.available | 2021-02-10T12:38:44Z | |
dc.date.issued | 2021 | es |
dc.identifier.citation | Tamayo Monsalve, M. A., Osorio, G., Montes, N. L., Lopez,S., Cubero, S. & Blasco, J (2021). Characterization of a Multispectral Imaging System Based on Narrow Bandwidth Power LEDs. IEEE Transactions on Instrumentation and Measurement, vol. 70, pp. 1-11, 2021, Art no. 2000111. | es |
dc.identifier.issn | 0018-9456 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11939/7084 | |
dc.description.abstract | Multispectral imaging systems using narrow-band power LEDs have become a feasible solution for a wide range of applications. Their fast response and simple implementation compensate for a low spectral resolution. In this article, we are filling a gap identified in the literature on multispectral systems by presenting a detailed design of a light controller, as well as a characterization of the whole system by means of a correlation and a repeatability analysis. We use a reference color target to assess accuracy and precision by comparing our system with high-performance hyperspectral equipment used in fruit quality control. The system captures multispectral images (MSIs) with 15 different wavelengths (λ ∈ [410 950] nm). The main finding is a Pearson correlation index above 80% (ρ > 0.8) with a variance in the measure within 10% (σ 2 <; 0.1). We also examine the characteristics of the instrument at a maximum speed of 8 MSIs/s although this entails sacrificing precision (σ 2 <; 0.3). | es |
dc.language.iso | en | es |
dc.publisher | IEEE Standards Association | es |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
dc.subject | Characterization | es |
dc.subject | Lighting control | es |
dc.subject | Measure instruments | es |
dc.subject | Multispectral imaging | es |
dc.title | Characterization of a Multispectral Imaging System Based on Narrow Bandwidth Power LEDs | es |
dc.type | article | es |
dc.authorAddress | Instituto Valenciano de Investigaciones Agrarias (IVIA), Carretera CV-315, Km. 10’7, 46113 Moncada (Valencia), España | es |
dc.entidadIVIA | Centro de Agroingeniería | es |
dc.identifier.doi | 10.1109/TIM.2020.3010109 | es |
dc.identifier.url | https://ieeexplore.ieee.org/abstract/document/9143139 | es |
dc.journal.issueNumber | 70 | es |
dc.journal.title | IEEE Transactions on Instrumentation and Measurement | es |
dc.page.final | 11 | es |
dc.page.initial | 1 | es |
dc.rights.accessRights | closedAccess | es |
dc.source.type | electronico | es |
dc.subject.agris | N01 Agricultural engineering | es |
dc.subject.agrovoc | Calibration | es |
dc.type.hasVersion | publishedVersion | es |